    Agilent 1260 HPLC G1315C Diode Array Detector
    The  Agilent 1260 G1315C Diode Array Detector allows you to add spectral
    acquisition to your HPLC analyses. The detector can verify separation
    quality with peak purity, multiple signals and spectral libraries, both
    interactively or automatically in the same run as your analytical
    quantification. The 1260 DAD offers an extended wavelength range from
    190 to 950 nm with the highest sensitivity or spectral resolution with
    programmable slit, along with holmium oxide wavelength verification for
    GLP compliance. The temperature management system ensures optimum
    baseline stability, even under rough ambient conditions. Two lamps in
    the Agilent 1260 Series diode-array detector ensure the highest light
    output for the lowest detection limits over the entire wavelength range.
    The use of 1,024 diodes and an optical slit programmable from 1 to 16
    nm ensures the best possible spectral bandwidth.
    All of our
    equipment is fully tested to perform at factory specifications before
    being shipped.  All tests were performed using Agilent Lab-Advisor.
    Tests are available upon request.
    Included with the Agilent 1260 HPLC G1315C DAD Detector:
    G1315 and cable
    HP Agilent 1260 HPLC G1315C Diode Array Detector Specifications
    Type
    Specification
    Detection type
    1024-element photodiode array
    Light Source
    Deuterium and tungsten lamps
    Wavelength range
    190 – 950 nm
    Short term noise (ASTM) single and multi-Wavelength
    ± 1 × 10-5 AU at 254 and 750 nm
    Drift
    2 × 10-3 AU/hr at 254 nm
    Linear absorbance
    range
    > 2 AU (upper limit)
    Wavelength Accuracy
    ± 1 nm
    Wavelength bunching
    1 – 400 nm
    Slit width
    1, 2, 4, 8, 16 nm
    Diode Width
    < 1 nm
    Available Flow Cells (only one included with the system - Semi-Mico)
    Standard:
    13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure
    maximum Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760
    psi) pressure maximum High pressure: 1.7 µl volume, 6 mm cell path
    length and 400 bar (5880 psi) pressure maximum 500 nano: 0.5 µl volume,
    10 mm cell path length and 50 bar (725 psi) pressure maximum
    Control and data evaluation
    Agilent ChemStation for LC
    Analog outputs
    Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
    Communications
    Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    Safety and maintainence
    Extensive
    diagnostics, error detection and display (through control module and
    ChemStation), leak detection, safe leak handling, leak output signal for
    shutdown of pumping system. Low voltages in major maintenance areas
    GLP features
    Early
    maintenance feedback (EMF) for continuous tracking of instrument usage
    in terms of lamp burn time with user-settable limits and feedback
    messages. Electronic records of maintenance and errors. Verification of
    wavelength accuracy with built-in holmium oxide filter.
    Housing
    All materials recyclable